Material tests
Evalution of the compatibility of nonmetallic materials for oxygen service.
Autogenous ignition temperature (AIT) in high pressure oxygen
- according to DIN EN ISO 11114, EN 1797, DIN EN ISO 3821: K9.3.1
- in oxygen athmosphere
- test temperature up to 500 °C
- test pressure up to 150 bar
Testing of materials for ignition sensitivity to gaseous oxygen impacts
- according to EN 1797, ISO 21010
- pressure surges up to 40 bar
- preheated oxygen up to 150 °C
Testing of materials for aging resistance
- according to ASTM G 114-14
- artificial aging over 100 hours
- pressure up to 100 bar
- temperature up to 150 °C